Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	64
Date	08/12/14
Start Time	11:38:31
Diameter Midpoint
 10.9	12892.4
 11.3	136942
 11.8	189021
 12.2	101677
 12.6	70370.2
 13.1	50770
 13.6	35853.5
 14.1	24898.7
 14.6	16511.5
 15.1	10171.5
 15.7	7239.32
 16.3	5027.23
 16.8	3138.6
 17.5	2379.02
 18.1	1875.47
 18.8	1326.94
 19.5	1158.5
 20.2	1099.97
 20.9	965.226
 21.7	908.94
 22.5	698.573
 23.3	1362.37
 24.1	1678.01
 25.0	1905.23
 25.9	1725.08
 26.9	1540.55
 27.9	1372.54
 28.9	1255.76
 30.0	1012.19
 31.1	827.395
 32.2	777.433
 33.4	686.46
 34.6	642.785
 35.9	519.343
 37.2	396.535
 38.5	327.686
 40.0	318.569
 41.4	285.983
 42.9	238.825
 44.5	223.592
 46.1	210.698
 47.8	178.56
 49.6	140.673
 51.4	159.556
 53.3	120.757
 55.2	108.951
 57.3	113.793
 59.4	121.23
 61.5	85.0776
 63.8	61.3018
 66.1	37.8468
 68.5	10.1939
 71.0	0
 73.7	0
 76.4	0
 79.1	0
 82.0	0
 85.1	0
 88.2	0
 91.4	28.2933
 94.7	199.992
 98.2	350.224
101.8	483.85
105.5	482.548
109.4	499.227
113.4	481.949
117.6	468.535
121.9	409.561
126.3	415
131.0	363.669
135.8	336.587
140.7	281.185
145.9	191.368
151.2	137.452
156.8	116.06
162.5	106.908
168.5	88.0998
174.7	51.7806
181.1	55.3494
187.7	33.6245
194.6	30.3244
201.7	26.7273
209.1	15.4324
216.7	22.3904
224.7	25.386
232.9	30.0054
241.4	21.8986
250.3	8.2583
259.5	11.726
269.0	15.9315
278.8	6.8797
289.0	15.8998
299.6	5.5141
310.6	16.8882
322.0	10.1569
333.8	10.7748
346.0	14.1141
358.7	7.34725
371.8	6.6275
385.4	4.49837
399.5	6.82865
414.2	0
429.4	4.72692
445.1	2.39365
461.4	4.88264
478.3	2.49105
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1641
High Voltage	9874.55
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	12.0193
Mean(nm)	13.9124
Geo. Mean(nm)	12.9092
Mode(nm)	11.7574
Geo. Std. Dev.	1.31678
Total Concentration(#/cm)	699280
Comment	